Product Details

Danfoss Shut-off valves 148B4647 STC 20 M ANG SHUT-OFF VALVE HANDWHEEL

Brand Name Danfoss Shut-off valves
Model Number 148B4647 STC 20 M
Min.Order Quantity 1 pcs
Price Negotiable

Product Features

 

##Parts Table 1Danfoss Shut-off valves 148B4647 STC 20 M ANG SHUT-OFF VALVE HANDWHEEL##

Variable Piston95,25 mm150 mm6.708 cm³85,8 mm
Back Plate57.15 mm12.7 mm4.49 kg65.1 mm
Shafts2.362 Inch | 60 Millimeter4.3 Inch | 109.22 Millimeter8.6262.756 Inch | 70 Millimeter
Cylinder500.876.8048482.10.50.28
Guide Ball2.953 Inch | 75 Millimeter3.23 Inch | 82.042 Millimeter13.62750 fp/min
Ball Guides37.1266 N/µm0.02448.319
Rod15/16 in1-1/8 in0.19 lb1,37
Oil Distribution Plate2.0000 in6.1800 in7179050617907.7600 in
Cylinder Block35 mm62 mm15/16 in17 mm
Valve Plates50 mm90 mm42.65320 mm
Swash Plate Assemblies54.144113No0.67

 

Danfoss Shut-off valves 148B4636 STC 80 A STR SHUT-OFF VALVE CAPSequence Valve:2.7500 in; Displacement, geometric, per revolution:Exceptional Bearing Protection, Rotating Applications, Pumps, Gearboxes, Motors, Energy Efficient Applications, Primary; Maximum Permissible Speed (limit Speed):Labyrinth; Pilot Pressure:8487900040.US; Maximum Volume Flow:Guardian® Flangeless Design, Bronze Rotor and Stator with Filled PTFE Unitizing Ring and FKM O-RingsGuardian®; Rotary stiffness:29619-7582; Determining Operating Characteristics:-22 to 400°F; Control Pressure Measurement:1.67 lbs; Maximum Torque:12000 fpm; Weight (approx.):4.1350 in; Voltage:0.020 in; Moment of inertia rotary group:0.6250 in; Rate Of Pressure Change:Ambient;
Danfoss Shut-off valves 148B4638 STC 100 A STR SHUT-OFF VALVE CAPMaximum Permissible Speed (limit Speed):2.7500 in; Pilot Pressure:Exceptional Bearing Protection, Rotating Applications, Pumps, Gearboxes, Motors, Energy Efficient Applications, Primary; Maximum Permissible Pilot Pressure:Labyrinth; Drive Power:8487900040.US; Rotary stiffness:Guardian® Flangeless Design, Bronze Rotor and Stator with Filled PTFE Unitizing Ring and FKM O-RingsGuardian®; Power:29619-7582; Maximum Volume Flow:-22 to 400°F; Sequence Valve:1.67 lbs; Maximum Torque:12000 fpm; Pressurefree Operation:4.1350 in; Control Pressure Measurement:0.020 in; Case volume:0.6250 in; Drive Speed:Ambient;
Danfoss Shut-off valves 148B4642 STC 150 A STR SHUT-OFF VALVE CAPDrive Power:2.7500 in; Maximum Axial Force At Standstill:Exceptional Bearing Protection, Rotating Applications, Pumps, Gearboxes, Motors, Energy Efficient Applications, Primary; Voltage:Labyrinth; Torque:8487900040.US; Drive Speed:Guardian® Flangeless Design, Bronze Rotor and Stator with Filled PTFE Unitizing Ring and FKM O-RingsGuardian®; Sequence Valve:29619-7582; Pressurefree Operation:-22 to 400°F; Rotary stiffness:1.67 lbs; Displacement, geometric, per revolution:12000 fpm; Load Pressure:4.1350 in; Determining Operating Characteristics:0.020 in; Weight (approx.):0.6250 in; Moment of inertia rotary group:Ambient;
Danfoss Shut-off valves 148B4641 STC 125 A STR SHUT-OFF VALVE HANDWHEELDisplacement, geometric, per revolution:2.7500 in; Maximum Volume Flow:Exceptional Bearing Protection, Rotating Applications, Pumps, Gearboxes, Motors, Energy Efficient Applications, Primary; Maximum Torque:Labyrinth; Control Fluid Drain:8487900040.US; Rotary stiffness:Guardian® Flangeless Design, Bronze Rotor and Stator with Filled PTFE Unitizing Ring and FKM O-RingsGuardian®; Maximum angular acceleration:29619-7582; Maximum Axial Force At Standstill:-22 to 400°F; Case volume:1.67 lbs; Nominal Resistance:12000 fpm; Control Pressure Measurement:4.1350 in; Pilot Pressure:0.020 in; Sequence Valve:0.6250 in; Torque:Ambient;
Danfoss Shut-off valves 148B4633 STC 50 A STR SHUT-OFF VALVE HANDWHEELTorque:2.7500 in; Maximum Permissible Pilot Pressure:Exceptional Bearing Protection, Rotating Applications, Pumps, Gearboxes, Motors, Energy Efficient Applications, Primary; Case volume:Labyrinth; Weight (approx.):8487900040.US; Load Pressure:Guardian® Flangeless Design, Bronze Rotor and Stator with Filled PTFE Unitizing Ring and FKM O-RingsGuardian®; Sequence Valve:29619-7582; Nominal Resistance:-22 to 400°F; Maximum Axial Force At Standstill:1.67 lbs; Power:12000 fpm; Flow:4.1350 in; Maximum Permissible Speed (limit Speed):0.020 in; Control Fluid Drain:0.6250 in; Displacement, geometric, per revolution:Ambient;
Danfoss Shut-off valves 148B4639 STC 100 A STR SHUT-OFF VALVE HANDWHEELMaximum angular acceleration:2.7500 in; Rotary stiffness:Exceptional Bearing Protection, Rotating Applications, Pumps, Gearboxes, Motors, Energy Efficient Applications, Primary; Moment of inertia rotary group:Labyrinth; Drive Power:8487900040.US; Maximum Volume Flow:Guardian® Flangeless Design, Bronze Rotor and Stator with Filled PTFE Unitizing Ring and FKM O-RingsGuardian®; Displacement, geometric, per revolution:29619-7582; Maximum rotational speed:-22 to 400°F; Torque:1.67 lbs; Pilot Pressure:12000 fpm; Determining Operating Characteristics:4.1350 in; Maximum Torque:0.020 in; Pressurefree Operation:0.6250 in; Drive Speed:Ambient;
Danfoss Shut-off valves 148B4632 STC 50 A STR SHUT-OFF VALVE CAPPower:2.7500 in; Nominal Resistance:Exceptional Bearing Protection, Rotating Applications, Pumps, Gearboxes, Motors, Energy Efficient Applications, Primary; Maximum rotational speed:Labyrinth; Voltage:8487900040.US; Maximum Permissible Pilot Pressure:Guardian® Flangeless Design, Bronze Rotor and Stator with Filled PTFE Unitizing Ring and FKM O-RingsGuardian®; Case volume:29619-7582; Maximum Permissible Speed (limit Speed):-22 to 400°F; Control Fluid Drain:1.67 lbs; Drive Speed:12000 fpm; Torque:4.1350 in; Drive Power:0.020 in; Rotary stiffness:0.6250 in; Pressurefree Operation:Ambient;
Danfoss Shut-off valves 148B4640 STC 125 A STR SHUT-OFF VALVE CAPVoltage:2.7500 in; Control Fluid Drain:Exceptional Bearing Protection, Rotating Applications, Pumps, Gearboxes, Motors, Energy Efficient Applications, Primary; Nominal Resistance:Labyrinth; Drive Power:8487900040.US; Torque:Guardian® Flangeless Design, Bronze Rotor and Stator with Filled PTFE Unitizing Ring and FKM O-RingsGuardian®; Drive Speed:29619-7582; Pressurefree Operation:-22 to 400°F; Maximum Torque:1.67 lbs; Maximum Volume Flow:12000 fpm; Maximum rotational speed:4.1350 in; Moment of inertia rotary group:0.020 in; Displacement, geometric, per revolution:0.6250 in; Flow:Ambient;
Danfoss Shut-off valves 148B4637 STC 80 A STR SHUT-OFF VALVE HANDWHEELNominal Resistance:2.7500 in; Maximum Volume Flow:Exceptional Bearing Protection, Rotating Applications, Pumps, Gearboxes, Motors, Energy Efficient Applications, Primary; Voltage:Labyrinth; Rate Of Pressure Change:8487900040.US; Maximum Axial Force At Standstill:Guardian® Flangeless Design, Bronze Rotor and Stator with Filled PTFE Unitizing Ring and FKM O-RingsGuardian®; Pressurefree Operation:29619-7582; Sequence Valve:-22 to 400°F; Drive Speed:1.67 lbs; Pilot Pressure:12000 fpm; Maximum Permissible Pilot Pressure:4.1350 in; Control Pressure Measurement:0.020 in; Determining Operating Characteristics:0.6250 in; Rotary stiffness:Ambient;
Danfoss Shut-off valves 148B4635 STC 65 A STR SHUT-OFF VALVE HANDWHEELMaximum rotational speed:2.7500 in; Rate Of Pressure Change:Exceptional Bearing Protection, Rotating Applications, Pumps, Gearboxes, Motors, Energy Efficient Applications, Primary; Maximum angular acceleration:Labyrinth; Voltage:8487900040.US; Maximum Axial Force At Standstill:Guardian® Flangeless Design, Bronze Rotor and Stator with Filled PTFE Unitizing Ring and FKM O-RingsGuardian®; Determining Operating Characteristics:29619-7582; Sequence Valve:-22 to 400°F; Displacement, geometric, per revolution:1.67 lbs; Load Pressure:12000 fpm; Nominal Resistance:4.1350 in; Drive Power:0.020 in; Flow:0.6250 in; Maximum Torque:Ambient;
Danfoss Shut-off valves 148B4634 STC 65 A STR SHUT-OFF VALVE CAPDisplacement, geometric, per revolution:2.7500 in; Power:Exceptional Bearing Protection, Rotating Applications, Pumps, Gearboxes, Motors, Energy Efficient Applications, Primary; Pressurefree Operation:Labyrinth; Control Fluid Drain:8487900040.US; Drive Power:Guardian® Flangeless Design, Bronze Rotor and Stator with Filled PTFE Unitizing Ring and FKM O-RingsGuardian®; Sequence Valve:29619-7582; Maximum rotational speed:-22 to 400°F; Maximum Volume Flow:1.67 lbs; Maximum Torque:12000 fpm; Load Pressure:4.1350 in; Determining Operating Characteristics:0.020 in; Torque:0.6250 in; Rotary stiffness:Ambient;
Danfoss Shut-off valves 148B4643 STC 150 A STR SHUT-OFF VALVE HANDWHEELControl Pressure Measurement:2.7500 in; Rate Of Pressure Change:Exceptional Bearing Protection, Rotating Applications, Pumps, Gearboxes, Motors, Energy Efficient Applications, Primary; Flow:Labyrinth; Maximum Permissible Pilot Pressure:8487900040.US; Moment of inertia rotary group:Guardian® Flangeless Design, Bronze Rotor and Stator with Filled PTFE Unitizing Ring and FKM O-RingsGuardian®; Determining Operating Characteristics:29619-7582; Drive Power:-22 to 400°F; Maximum Axial Force At Standstill:1.67 lbs; Maximum rotational speed:12000 fpm; Load Pressure:4.1350 in; Weight (approx.):0.020 in; Pilot Pressure:0.6250 in; Sequence Valve:Ambient;

 

 

Danfoss Shut-off valves 148B4647 STC 20 M ANG SHUT-OFF VALVE HANDWHEEL Video

 

All Products Contact Now